Sprinkler Winterization · San Antonio, New Braunfels & surrounding areas

San Antonio Sprinkler Winterization

Texas winters are mild — until they aren’t. When a hard freeze hits, water trapped in your backflow, valves, and lines can freeze, expand, and crack the system. AAIS drains, protects, and — when you want full peace of mind — air-blows your sprinklers before the cold arrives.

★★★★★ 4.8-Star Average 1,200+ Reviews Locally Owned Since 2003
Free On-Site Estimate
We quote before any work
Air-Compressor Blowout
High-pressure — every drop out
Backflow Protection
The #1 freeze risk, covered
Locally Owned
Trusted since 2003
★ Est. 2003 · Locally Owned & Operated Sprinkler Winterization

Do You Need to Winterize in Central Texas?

Central Texas isn’t the frozen north — you don’t have to blow your system out every single year. But the freezes we’ve had lately across San Antonio and New Braunfels are exactly the kind that crack backflows and split pipes.

Your system is underground, but its most vulnerable parts — the backflow preventer, exposed valves, and above-ground piping — sit right out in the cold. A little prep before the first hard freeze beats an expensive repair come spring.

Hard Freezes Happen
Texas has seen real, damaging freezes in recent winters — not every year, but often enough to matter.
Backflows Crack First
Above-ground backflow preventers are the #1 freeze-damage point on most Texas systems.
Hidden Until Spring
A freeze split often shows no signs until you turn the system on and find a leak.
Cheaper Than Repairs
A winterization visit costs far less than replacing cracked valves, backflows, or pipe.
23+
Years in Business
1,200+
Five-Star Reviews
★★★★★
4.8-Star Average
FREE
On-Site Estimates
The real freeze risk

Your Backflow Preventer Freezes First

On almost every Texas system, the part most likely to crack in a freeze is the backflow preventer — that brass or PVC assembly sticking up out of the ground near your water main.

Water sitting inside it has nowhere to go when it freezes and expands. We drain it, shut it down the right way, and can insulate or cover it so a sudden cold snap doesn’t split the body.

Above-ground backflow & valves drained and shut down correctly
Insulated covers available for exposed components
We catch worn or weak parts before the freeze finds them
Above-ground irrigation backflow preventer being winterized and insulated in San Antonio
What we protect

What Our Winterization Covers

We work through every part of your system that a freeze can reach.

Backflow Preventer
Drained, shut down & insulated against a hard freeze
Valves & Manifolds
Cleared of trapped water that can crack the body
Sprinkler Heads
Water pushed out of the heads and low spots
Mainline & Lateral Lines
Pressure relieved so nothing splits underground
Drip Zones
Filters and lines cleared — the easiest parts to overlook
Controller / Timer
Set to off or rain mode so it won’t run in a freeze
How we work

Our Winterization Process

A thorough shutdown built around Texas weather — not a northern blow-and-go.

01

Shut Off the Supply

We close the irrigation supply valve and isolate the system from your water.

02

Drain the System

We open drains and clear water from heads, valves, and lines.

03

Air-Compressor Blowout (Upgrade)

Optional high-pressure blowout forces out every last drop, zone by zone.

04

Protect the Backflow

We shut down and insulate the backflow and any exposed components.

05

System Inspection

We flag worn nozzles, weak valves, and leak-prone fittings for spring.

06

Controller & Walkthrough

We set the timer to rain/off and show you exactly what we did.

Free on-site estimate Air-compressor blowout available Get a Free Estimate
AAIS technician using an air compressor to blow out a sprinkler zone in San Antonio High-pressure air clears every zone — the most thorough option
Straight talk

Do You Really Need a Full Blowout in Texas?

Honest answer: not every year. Central Texas doesn’t get the long, deep freezes that force a full blowout up north. Most winters, draining the system and protecting the backflow is plenty.

When a blowout is worth it:

A hard freeze is in the forecast and you want every drop out of the lines
You’ve had freeze damage before, or have a lot of exposed above-ground pipe
You’re leaving town and won’t be here to protect the system
You simply want maximum peace of mind — we run high-pressure air through every zone
Should you book?

Signs It’s Time to Winterize

If any of these sound familiar, it’s time to get on the schedule.

Freeze in the Forecast
Overnight lows near or below freezing in the next few days.
Exposed Backflow & Pipe
Above-ground components with no insulation or cover.
You’ve Frozen Before
A past freeze cracked a valve, head, or backflow.
Controller Still Running
Your timer is still watering as the season turns cold.
Older System
Aging valves and fittings get brittle and split in a freeze.
Heading Out of Town
Nobody home to protect the system during a cold snap.
See it for yourself

Why San Antonio Trusts AAIS

Over two decades protecting San Antonio, New Braunfels & surrounding-area systems through every freeze and every season.

Built right here in our hometown

A Homegrown Business, Not Just Another Contractor

Chris Mayberry started All American Irrigation Systems in 2003, at just 18 years old, passing out flyers door-to-door in the neighborhood he grew up in. Over 20 years later, AAIS is one of the most trusted irrigation companies in the San Antonio area — relied on by HOA boards, national brands, and regional property groups, with a team that still shows up with the same pride and professionalism on every job.

“

People buy from people, not companies.

— A lesson from Chris’s grandfather
All American Irrigation Systems branded service trucks parked along a San Antonio neighborhood street
Local trucks, on the road across San Antonio, New Braunfels & the surrounding areas
Winterization FAQ

Sprinkler Winterization Questions, Answered

What San Antonio and New Braunfels homeowners ask us most about winterizing.

Not every year like up north, but a hard freeze can still crack your backflow, valves, or pipes. Draining and protecting the system is cheap insurance against an expensive spring repair.
A standard winterization drains the system and protects the backflow. A blowout adds high-pressure air to force out every last drop — the most thorough option for a hard freeze.
The ideal window is October 1 through December 15. Booking early helps you beat the first freeze and avoid the seasonal rush.
The above-ground backflow preventer and any exposed valves or piping. That’s where most freeze damage starts.
A cover helps, but trapped water can still freeze. We drain and shut it down properly, and can add insulation for full protection.
Yes — we run seasonal winterization and blowout specials. Call and ask what’s available when you schedule.
Shut off the irrigation supply, set the controller to off or rain mode, and protect the backflow. If you’re not sure, give us a call.
Yes. We flag worn nozzles, stuck valves, and leak-prone fittings so any repairs can be planned for spring.
Know your system

The 3 Backflow Preventers — and How to Protect Yours

Texas irrigation systems use one of three backflow assemblies, and each gets shut down a little differently before a freeze. The basic idea is the same — set the shutoff valves and test cocks to a 45° angle so no water stays trapped, then insulate the assembly — but here’s how to tell which one you have. Not sure which you have? We can identify and winterize all three.

Tap to enlargeDouble check assembly (DCA) backflow preventer being winterized in San Antonio
Double Check Assembly (DCA)Two check valves in series, usually mounted low or in-line near your main. Common on lower-hazard residential systems.
Tap to enlargePressure vacuum breaker (PVB) backflow preventer mounted above ground in San Antonio
Pressure Vacuum Breaker (PVB)A single check with a spring-loaded air vent under a bonnet, mounted up high above the heads — the most freeze-exposed of the three.
Tap to enlargeReduced pressure (RP / RPZ) backflow assembly with relief valve in San Antonio
Reduced Pressure Assembly (RP)Two checks plus a relief valve for the highest protection. Heavier-duty, and the relief valve is especially freeze-sensitive.

How to Winterize Your Backflow Preventer

All three assemblies are protected the same basic way, and it only takes a flathead screwdriver. The goal is simple: never leave water sealed inside the valve body, where it can freeze, expand, and crack the brass.

1Using a flathead screwdriver, turn each test cock to a 45° angle — about halfway. A double check (DCA) and reduced pressure (RP) assembly have four; a pressure vacuum breaker (PVB) has two.
2Turn both shutoff valves (inlet and outlet) to a 45° angle as well — not fully open, and not fully closed.
3Why 45°? At a partial angle, no water gets trapped on either side of a valve or test cock, so if it freezes it can expand and escape instead of splitting the assembly.
Tap to enlarge Green insulated backflow preventer cover bag sold by All American Irrigation Systems
Need an Insulated Backflow Cover?

Slipping an insulated cover over the whole assembly is the single best freeze protection there is. We keep these insulated backflow bags in stock — just give us a call and we’ll bring one out and fit it for you.

Call (210) 826-6474
Beat the first freeze

Protect Your System Before the Freeze

Get your sprinklers drained, your backflow protected, and an optional air-compressor blowout — all before the next hard freeze hits San Antonio, New Braunfels, or the surrounding areas. Ask about our seasonal blowout special.

Free on-site estimate
Air-compressor blowout available
Backflow freeze protection
Call us today — we answer (210) 826-6474 or Get a Free Estimate